Navigation
Navigate Navigate Navigate Navigate Navigate Navigate Navigate Navigate Navigate Navigate Navigate

IFCHVACDOMAIN

The data model consists of the following:

31  Entities
31  Enumerations

The IfcHvacDomain schema in the domain layer defines basic object concepts required for interoperability within the heating, ventilating and air conditioning (HVAC) domain. It extends concepts defined in the IfcSharedBldgServiceElements schema.

Scope

The scope of the IfcHvacDomain schema is defined as:

  1. The segments, fittings and connections that constitute duct and piping distribution systems typically used for building services, such as for air conditioning, ventilation and exhaust-air systems; chilled water, steam and heating hot water, potable water, waste, natural gas and LPG systems, etc.
  2. Equipment typically used in building services systems, such as boilers, chillers, fans, pumps, etc., and the vibration isolation associated with these components.
  3. Terminal and flow control devices, such as air vents and grilles, variable air volume modulators, valves, dampers, etc.

Out of Scope

The following are deemed to be out of scope of the IfcHvacDomain schema at this time:

Occurrence

Classes within this schema define only types of elements that are used in heating, ventilating and air conditioning building services where subtypes of IfcDistributionElementType have been elaborated in the IfcSharedBldgServiceElements schema to mirror their corresponding occurrence entities. Refer to the schema description for the IfcSharedBldgServiceElements for more information about concepts of type, occurrence and performance history.

The objective is that a specific element type is defined only once in an IFC exchange. Occurrences of elements that are related to these types are defined by instances of related subtypes of IfcDistributionElement (also defined in the IfcSharedBldgServiceElements schema). Details of the relevant occurrence subtype are provided in the documentation for each type.

HISTORY This schema has been significantly modified in IFC R2x2. Refer to the change log and issues resolution database for details.

Interfaced schemas (12):

REFERENCE FROM IFCACTORRESOURCE
REFERENCE FROM IFCDATETIMERESOURCE
REFERENCE FROM IFCEXTERNALREFERENCERESOURCE
REFERENCE FROM IFCGEOMETRYRESOURCE
( IfcAxis2Placement3D,
IfcCurve,
IfcCircle,
IfcEllipse,
IfcPolyline,
IfcTrimmedCurve,
IfcLine,
IfcCompositeCurve,
IfcBezierCurve);
REFERENCE FROM IFCKERNEL
REFERENCE FROM IFCMATERIALRESOURCE
( IfcMaterial);
REFERENCE FROM IFCMEASURERESOURCE
( IfcNamedUnit);
REFERENCE FROM IFCPRODUCTEXTENSION
REFERENCE FROM IFCPROFILERESOURCE
REFERENCE FROM IFCPROPERTYRESOURCE
REFERENCE FROM IFCSHAREDBLDGSERVICEELEMENTS
( IfcEnergyConversionDeviceType,
IfcFlowMovingDeviceType,
IfcFlowControllerType,
IfcFlowFittingType,
IfcFlowStorageDeviceType,
IfcFlowTerminalType,
IfcFlowTreatmentDeviceType,
IfcFlowSegmentType);
REFERENCE FROM IFCSHAREDCOMPONENTELEMENTS
( IfcDiscreteAccessoryType);

Entities (31):

Go to Diagram 4 IfcAirTerminalBoxType
Go to Diagram 3 IfcAirTerminalType
Go to Diagram 1 IfcAirToAirHeatRecoveryType
Go to Diagram 1 IfcBoilerType
Go to Diagram 1 IfcChillerType
Go to Diagram 1 IfcCoilType
Go to Diagram 3 IfcCompressorType
Go to Diagram 1 IfcCondenserType
Go to Diagram 1 IfcCooledBeamType
Go to Diagram 1 IfcCoolingTowerType
Go to Diagram 4 IfcDamperType
Go to Diagram 2 IfcDuctFittingType
Go to Diagram 2 IfcDuctSegmentType
Go to Diagram 2 IfcDuctSilencerType
Go to Diagram 1 IfcEvaporativeCoolerType
Go to Diagram 1 IfcEvaporatorType
Go to Diagram 3 IfcFanType
Go to Diagram 2 IfcFilterType
Go to Diagram 4 IfcFlowMeterType
Go to Diagram 3 IfcGasTerminalType
Go to Diagram 1 IfcHeatExchangerType
Go to Diagram 1 IfcHumidifierType
Go to Diagram 2 IfcPipeFittingType
Go to Diagram 2 IfcPipeSegmentType
Go to Diagram 3 IfcPumpType
Go to Diagram 1 IfcSpaceHeaterType
Go to Diagram 4 IfcTankType
Go to Diagram 1 IfcTubeBundleType
Go to Diagram 1 IfcUnitaryEquipmentType
Go to Diagram 4 IfcValveType
Go to Diagram 4 IfcVibrationIsolatorType

Enumerations (31):

Go to Diagram 4 IfcAirTerminalBoxTypeEnum
Go to Diagram 3 IfcAirTerminalTypeEnum
Go to Diagram 1 IfcAirToAirHeatRecoveryTypeEnum
Go to Diagram 1 IfcBoilerTypeEnum
Go to Diagram 1 IfcChillerTypeEnum
Go to Diagram 1 IfcCoilTypeEnum
Go to Diagram 3 IfcCompressorTypeEnum
Go to Diagram 1 IfcCondenserTypeEnum
Go to Diagram 1 IfcCooledBeamTypeEnum
Go to Diagram 1 IfcCoolingTowerTypeEnum
Go to Diagram 4 IfcDamperTypeEnum
Go to Diagram 2 IfcDuctFittingTypeEnum
Go to Diagram 2 IfcDuctSegmentTypeEnum
Go to Diagram 2 IfcDuctSilencerTypeEnum
Go to Diagram 1 IfcEvaporativeCoolerTypeEnum
Go to Diagram 1 IfcEvaporatorTypeEnum
Go to Diagram 3 IfcFanTypeEnum
Go to Diagram 2 IfcFilterTypeEnum
Go to Diagram 4 IfcFlowMeterTypeEnum
Go to Diagram 3 IfcGasTerminalTypeEnum
Go to Diagram 1 IfcHeatExchangerTypeEnum
Go to Diagram 1 IfcHumidifierTypeEnum
Go to Diagram 2 IfcPipeFittingTypeEnum
Go to Diagram 2 IfcPipeSegmentTypeEnum
Go to Diagram 3 IfcPumpTypeEnum
Go to Diagram 1 IfcSpaceHeaterTypeEnum
Go to Diagram 4 IfcTankTypeEnum
Go to Diagram 1 IfcTubeBundleTypeEnum
Go to Diagram 1 IfcUnitaryEquipmentTypeEnum
Go to Diagram 4 IfcValveTypeEnum
Go to Diagram 4 IfcVibrationIsolatorTypeEnum